Skip to main content

BLOOD DONOR ( Qualirty Control )

 Quality control measures 


 

1 - Form Revision Batch numbers of blood near daily.  

2 - form figures are prepared daily units.

 3 - records are complete donor complications daily. 

 4 - is complete and review all information on the history and medical examination of the donor also came the donation form.

 5 - Check your blood near to detect any manufacturing defects or change the color of clotting blocker for each donor.

 6 - Check the accuracy of the blood mixing devices by using different weights information every day and record the results of the calibration equipment in the form of quality.

 Way 1 - before the start of the donation be logged unit number and the name of the donor on the major blood bladders and proximity thereto and a donation form three tubes with a red cover.

 2 - then putting bladders blood on a blood mixing with the delivery of who your Balqrbh device. 

 3 - Check the arm of the donor to determine the appropriate vein, often in the soles of the elbow.  

4 - Put القماط and select the appropriate vein, and then unzip it.
5 - Set up an arm of the donor: - Wipe the arm of the donor from the point to be Khozha for a distance of 4 cm in all directions using the swab iodine 2% for 30 seconds (use swabs Alaksudain or green soap with Donor sensitivity to iodine or alcohol swabs in the absence of such smears.).
 
Wipe Bmshat iodine 10% starting from the middle in a circular motion a spiral, going into the outside for 30 seconds.
 
Cover the area with sterile gauze 4 X 4 and do not touch the skin of the donor again.  

6 - Place القماط again.
7 - Remove the needle cover and tingling donated by inserting the needle into a vein straight movement is hesitant with the observation that the direction of the needle to the highest slot.

 8 - proven needle arm donated medical using plaster.

 9 - Turn on the mixing of blood.  

10 - ask the donor to open and close his fist (pressure on the rubber ball every 10 - 12 seconds).

 11 - Upon completion of the withdrawal of 469 cm (585 g), the device automatically stop the clouds with the launch of a siren (the drawing is complete within 10 - 15 minutes, if within 10 minutes can prepare all blood products from the unit, but if in 15 minutes can only obtain concentrated red blood cells with the execution of plasma rich in platelets, and in the event that exceeded 15 minutes is dispensed and the execution of the entire unit).
12 - Place Alklamb on who near the needle and make a knot Court prepared by the node under a needle and Alklamb place directly.  

13 - Disconnect by Clipper between node Court, Alklamb and unplug the unit of blood. 14 - Take samples by open Alklamb then close it again.

 15 - unpack القماط then drag the needle, and then clicking by a piece of gauze with the lifting arm of the donor.  

16 - Dispose of the needle in the container provided.
17 - Log time beginning and end of the donation and the final weight of the unit of blood.  

18 - then who meat bottom node court then mix blood Balely the bagpipes blood three times and then divide who to pieces connected by welding gases that contain every piece Ali who number printed.  

19 - Remove the first piece put unit number and then place it in a collection pieces for daily mechanisms. 

 20 - send all units of blood collected to room Apheresis.

21 - Put pipe with red cover down in Alrak and send for blood safety Nhaleil and confirm the blood type. 

 22 - complete the donation form.

 23 - Check the place to donate and if proper medical Put plaster.

 24 - Allow the donor to do with staying with him.

 25 - give donated juice and biscuits, and بملاحظته. 26 - Allow the donor to leave after a 10-minute break and the absence of any complications donation.  

Comments

Popular posts from this blog

Stool Analysis

                                      Stool Analysis

MICROSCOPIC URINALYSIS

MICROSCOPIC URINALYSIS   Methodology A sample of well-mixed   urine (usually 10-15 ml) is centrifuged in a test tube at relatively low speed (about 2-3,000 rpm) for 5-10 minutes until a moderately cohesive button is produced at the bottom of the tube. The supernatant is decanted and a volume of 0.2 to 0.5 ml is left inside the tube. The sediment is resuspended in the remaining supernatant by flicking the bottom of the tube several times. A drop of resuspended sediment is poured onto a glass slide and coverslipped.

Liver Enzymes

Liver Enzymes   Definition A liver enzyme is a protein that helps to speed up a chemical reaction in the   liver. Liver function tests are blood tests that are used to evaluate various functions of the liver - for example, metabolism, storage, filtration and excretion, which are often performed by liver enzymes. However, not all liver function tests are measures of enzyme function. • ALT - (alanine aminotransferase )   - was previously called SGPT is more specific for liver damage. The ALT is an enzyme that is produced in the liver cells (hepatocytes) therefore it is more specific for liver disease than some of the other enzymes. It is generally increased in situations where there is damage to the liver cell membranes. All types of liver inflammation can cause raised ALT.    • AST - (aspartate aminotransferase) which was previously called SGOT. This is a mitochondrial enzyme that is also present in heart, muscle, kidney and brain therefore it is less specific